Canon Pellix

In the mid 1960s through the lens exposure metering (TTL) was the new technology entering the SLR camera market. The Pellix was Canon's answer to that challenge. This technology was first successfully realised in a 35mm SLR camera in the remarkable Tokyo Kogaku KK Topcon RE-Super, launched in 1963[1], but followed by the Pentax Spotmatic a year later.[2] Unlike the RE Super, the Pellix and the Spotmatic TTL exposure meter relies on stopping down the lens to measure the light, making the finder image dimmer. However, all have quite different approaches accomplishing the TTL metering, and Canon possibly the most unusual one, using a semitransparent stationary reflex mirror behind which a metering cell is raised during the reading. [3] In October 2010, the Sony Corporation launched the Sony Alpha SLT-a55 based on the pellicle mirror principle, but now called the Translucent Mirror technology.

Contents

The First Canon with TTL

Canon's sudden switch from professionally oriented SLR cameras to advanced amateur cameras happened in March 1964 when they left the Canon Canonflex range and launched the Canon FX with the FL lens mount. It has a built in CdS exposure meter with a circular window on the right-hand camera front. The Canon FP without exposure meter was added later the same year. The cameras were well built, but the metering technology was several years behind the Minolta SR-7 which pioneered that technology in 1962[4]. Then just half a year later, in the spring of 1965 Canon surprised the camera community with the remarkable Pellix. The new camera featured the much-expected TTL exposure metering facility, albeit employing the stop-down metering method.

However, what makes the Pellix special, is that the TTL metering is accomplished using a stationary semitransparent pellicle reflex mirror instead of the traditional moving SLR mirror and placing a CdS meter cell behind it for the TTL exposure measurement. The cell, attached to an arm is swung up in front of the film gate by pushing the stop down lever on the right-hand camera front, reading the light projected from the camera lens after passing through the semitransparent mirror. Very few alternative locations inside the camera were available for picking up light rays from the camera lens. The Topcon RE Super has its meter cell placed directly behind the reflex mirror into which a pattern of slits are cut to let the light though, while the Spotmatic has a pair of cells located either side of the finder window reading light off the focusing screen.

The stop-down lever at the left-hand camera front also operates the self-timer. Pushing the lever towards the lens activates the stop down match-needle meter, while pulling in the opposite direction winds the timer. As with the Canon FX and FP, the camera back is opened turning a key at the base. The film speed is set lifting and turning the rim of the shutter speed dial. The camera is designed for the obsolete 1.35 volt mercury battery, which fortunately may be directly replaced by a similar 1.4 volt hearing aid battery, it is usable for about a year after activation whether used or not. The battery compartment is at the left-hand edge of the camera, next to the rewind knob. The Pellix was replaced by the improved Canon Pellix QL first marketed in March 1966. Improvements included the addition of a quick film loading mechanism and contacts in the base of the battery compartment for a separately available electronic booster for the internal exposure meter. [5]

The pellicle mirror

The semitransparent fixed mirror in the Pellix, for the first time successfuly used in a 35mm SLR camera, lets about two-thirds (66%) of the light from the lens pass directly through to the film, while the rest is reflected to the viewfinder. [6] The object of this arrangement - apart from accomplishing TTL metering, is for a simpler construction, a less noisy operation, and to get rid of the finder blackout during exposure. That is a favourable proposition, but the design has its flaws; the obvious one being loss of light, about one half stop (f/1.2) in the exposure through the semitransparent mirror, and about one and three-fourth stop (f/1.7) dimmer finder compared to using a fully reflecting mirror. A more serious problem however, is that the image forming light rays has to pass through the stationary pellicle mirror - in itself an obstruction, but over time the mirror surfaces also become soiled; it scatters the light and therefore degrades the projected image that forms the image on the film. If this occurs, or the fragile mirror is damaged in any way it has to be replaced.

It is true the finder does not go black during exposure, but at small lens apertures, the eye has no time to adjust to the dark finder. The operating noise from the Pellix is surprisingly similar to that of the Canon FX using a moving reflex mirror. Canon made two fast lenses, the FL 50mm 1:1.4 and the FL 58mm 1:1.2, in order to compensate for the light loss, but fast lenses might increase the risk of the sun burning holes in the shutter curtain not being protected by a solid mirror; a fact anticipated and solved by providing the Pellix with a metal shutter curtain. Another obstacle is the risk of light finding its way into the camera by way of the finder window during exposure, since there is no mirror to block the path in its up-position. This was also anticipated, and a finder blind is provided which is operated by turning the ring under the rewind knob, especially useful when leaving the camera on a stand. The Meter circuit is susceptible to breakage due to the CdS meter arm being moved into position behind the pellicle mirror during exposure reading. Two special lenses were made available for the Canon Pellix, utilising the fact the camera has a stationary mirror that will not hit the lens' rear element; the FLP 19mm 1:3.5 and the FLP 38mm 1:2.8. The FLP code shows that these lenses are for the Pellix camera. [7]

References

  1. ^ Marco Antonetto, Claudio Russo (1997). Topcon Story. Nassa Watch Gallery Collector camera publishing. ISBN 8887161003. 
  2. ^ Danilo Cecchi (1990). Asahi Pentax and Pentax SLR 35mm cameras 1952-1989. Hove Foto Books. ISBN 0906447623. 
  3. ^ Rudolph Lea (1993). The Register of 35mm Single Lens Reflex Cameras Second Ed.. Wittig Books Hückelhoven. ISBN 3889841309. 
  4. ^ A.R. und J. Scheibel (1990). Minolta's Kamera Technik - Von der Nifcalette bis zu Riva und Dynax. G+G Urban-Verlag, Ahrensburg. ISBN 3925334475. 
  5. ^ Peter Dechert (1992). Canon Single Lens Reflex Cameras 1959-1991. Historical Camera Publications, Washington. ISBN 1879561042. 
  6. ^ Rudolph Lea (1993). Register of 35mm SLR cameras. Wittig Books, Hückelhoven. ISBN 3889841309. 
  7. ^ Ivor Matanle (1996). Collecting and using Classic SLRs. Thames & Hudson. ISBN 0500279012. 

External links